Stop first if
- Attic access is needed.Walk on framing only, and stop if framing moves or cracks.
- Heavy mold is found.Keep people out and call a specialist.
- The deck sags or feels soft from below.Keep people off the roof and call an engineer.
01
Ask on the call
5Homeowner? These are the questions a good technician will ask you. Having the answers ready makes the first visit count.
- What did you see, and where in the attic?
- Has siding, soffit or insulation work been done lately?
- Do bath fans or a dryer vent into the attic?
- Do you run a humidifier?
- Is it a vented attic, or a cathedral or sealed roof?
02
Bring
6- Flashlight
- Temperature and humidity meter with dew point
- Moisture meter
- Thermal imager
- Tape measure
- Phone for photos
03
Check on site
6- Check intake before exhaust. Look for a clear channel at the eaves, baffles and soffit dams.
- Compare intake and exhaust. A vented soffit label does not give a size.
- Look for daylight at the ridge slot, and note crushed vent or mixed exhaust types.
- Note recent work that closed vents. Do not add vents over blocked intake.
- Check air leaks, bath fans and humidifiers.
- On cathedral or unvented roofs, record the layers, climate zone, and vented or unvented.
04
Keep on the record
4- Photos of mold or frost by location
- Intake and exhaust areas measured
- Temperature, humidity and dew point
- Recent work near the eaves
General guidance for a qualified person, not a finding about any home. The person on site decides.