Stop first if
- Anyone is in the water while suction cleaning runs with vacuum release suspended.Stop the pump if it can be done without risk. Get everyone out of the water.
- An equipment room is flooding, or water reaches powered equipment.Stay out of the water. Shut off power only if it can be done without risk. Call a licensed electrician.
- Someone proposes entering a buried surge tank or pit.Do not enter. Treat it as a confined space and call a trained confined space crew.
01
Ask on the call
6Homeowner? These are the questions a good technician will ask you. Having the answers ready makes the first visit count.
- Did anyone touch a valve or service anything right before this started?
- What speed is the pump running, and who set the schedule?
- Does it happen at a certain time of day, like hot afternoons?
- Is it weak only when the cleaner, jets or a water feature runs?
- When were the baskets and filter last cleaned?
- Is a heater, booster or solar loop on the same system?
02
Bring
5- Suction and discharge gauges
- Valve position sketch sheet
- Reference thermometer
- Flashlight
- Gloves
03
Check on site
6- Read the pump display for actual speed, drive temperature and event log first.
- With the pump off, walk every valve against the selected mode and look for left-in plugs.
- Clean the baskets, then compare flow at each return at one known speed.
- Switch each cleaner, booster or feature on and off, and log speed and filter pressure.
- On a variable speed pump, change one valve at a time and watch for speed rising.
- Match low-flow times to heat alerts, and check the fan path with power off.
04
Keep on the record
4- Pump speed, program type and event log
- Sketch of valve positions by mode
- Filter pressure at a stated speed
- Run schedule for booster, cleaner and features
General guidance for a qualified person, not a finding about any home. The person on site decides.