Stop first if
- Gas smell, a carbon monoxide alarm, or soot at a gas water heaterGet everyone out and call the gas utility from outside. Nobody works on the heater.
- Water has reached outlets, a panel or the wiring of a sensor faucetStay out of the water. Call the electric utility or a licensed electrician before anyone goes in.
- Water runs and will not shut off at the fixture stop, a branch valve or the mainKeep people and power away from the water and call for emergency plumbing service now.
01
Ask on the call
7Homeowner? These are the questions a good technician will ask you. Having the answers ready makes the first visit count.
- Which fixture is weak, in which room, and what brand is it if you can read it?
- Does water come out weak when it is on, drip when it is off, or drain slowly?
- Is it weak on hot, cold or both at that fixture?
- Did it start after plumbing work, a new faucet, cartridge or aerator, or a freeze?
- Is the shutoff under it fully open, and has anyone cleaned the aerator or showerhead?
- Do faucets on this floor and other floors run normally, hot and cold?
- Is the hot water from a tankless heater or a tank, and are you on city water or a well?
02
Bring
6- Aerator key and spare screens
- Bucket and a timer
- Descaler and a small brush
- Pressure gauge for a hose bibb
- Spare supply connectors
- Flashlight
03
Check on site
7- Run a faucet on another floor or branch, hot and cold. If it is weak too, handle it as a house-wide pressure problem, not this fixture.
- At the weak fixture, run hot and then cold. An aerator serves both sides, so weak on one side only points behind it.
- Open the stop under the fixture and the handle all the way, counting the turns, and test hot and cold again.
- Shut the water to the fixture, then remove and clean the aerator, showerhead or sprayhead screen. Test hot and cold again.
- Read the faucet or valve brand first. With the water shut, lift the cartridge and clear scale or debris from its ports. A balancing shower valve needs both supplies open.
- On a tankless heater, open every valve and watch its flow display. If other hot taps run fine, the heater is not where it starts. Its filter is a technician's job.
- Look behind the fixture for a kinked or clogged connector, many fittings, or old galvanized pipe. A licensed plumber re-pipes a restricted run.
04
Keep on the record
5- Fixture room, type and brand, with a photo of the label or old part
- Timed bucket fill on hot and on cold, before and after each step
- Stop position and how many turns it took to open fully
- Which other taps were tried, and whether any was weak
- Photo of what came out of the aerator or cartridge
General guidance for a qualified person, not a finding about any home. The person on site decides.