Stop first if
- Someone has capped or plugged the relief valve or relief pipe on a working heaterTreat it as an explosion risk. Keep people clear and call a licensed plumber now. Turn the heater off only if it can be done without risk.
- Hot water is pouring from the relief valveKeep clear of the discharge because it can scald. Turn the heater off only if it can be done without risk. Call a qualified technician now.
- You smell gas, including a rotten-egg smell near the heaterLeave the building now. From outside, call emergency services or the gas utility.
- Water is standing around a heater that has powerStay out of the water. Shut off power only if it can be done without risk. Otherwise call the electric utility or a licensed electrician.
01
Ask on the call
6Homeowner? These are the questions a good technician will ask you. Having the answers ready makes the first visit count.
- Is it a slow drip, short spurts, or a big flow of hot water?
- Does it happen while the water is heating, or all the time?
- Has anyone capped or plugged the discharge pipe?
- Is there a small tank on the cold line near the heater?
- Is there a pressure regulator, softener or check valve on the water line?
- How old is the heater?
02
Bring
5- Pressure gauge with a maximum-reading pointer
- Air gauge for the expansion tank valve
- Thermometer
- Gloves and eye protection
- Flashlight
03
Check on site
6- Find where the water comes from: relief line, a fitting or the tank body. Look for any cap or plug.
- List each one-way device on the line. Ask the water utility about the meter.
- Fit a gauge at a hose bibb or heater drain. Record static with the heater idle. Then watch it through a heat-up while no water is used.
- A rise only during heating may point toward trapped expansion. High pressure all the time may point toward supply or the regulator.
- If a tank is present, turn heater power off first. Drain the water side down to no pressure, then read the air charge.
- A qualified person works the relief lever only with the discharge piped to a drain and nobody in its path.
04
Keep on the record
5- Pressure readings at rest and across a heating cycle
- Photo of the discharge line from the valve to its end
- List of one-way devices and regulators
- Expansion tank air reading and incoming static
- Heater nameplate, plus the test tag on any backflow assembly
General guidance for a qualified person, not a finding about any home. The person on site decides.