Stop first if
- You smell gasLeave the building now. From outside, call emergency services or the gas utility.
- A CO alarm soundsGet everyone into fresh air. Call emergency services from outside.
- After resets, an oil burner chamber holds pooled oil or vapor, or runs very hotDo not press reset. Keep the burner off and call a licensed oil burner technician.
- Water is on wiring or controlsKeep clear of it. A qualified person kills power at the disconnect while standing somewhere dry. Otherwise call a licensed electrician.
01
Ask on the call
6Homeowner? These are the questions a good technician will ask you. Having the answers ready makes the first visit count.
- Is it gas or oil?
- What happens when the thermostat calls for heat?
- Does it show a code or blinking light, and can you read it before any reset?
- How many times has anyone pressed reset?
- Have you checked the thermostat, power switch and oil level?
- Does the furnace or its drain sit somewhere cold, like a garage, attic or crawl space?
02
Bring
5- Digital manometer
- Meter with a microamp range
- Combustion test instruments
- Draft gauge
- Flashlight
03
Check on site
6- Record fuel, ignition type and venting. Pull stored faults while power and the door are still untouched.
- Look through the sight glass during a heat call. Mark where the start-up stops.
- On oil, ask about resets and look for pooled oil before any restart.
- A licensed tech reads what that safety device senses, such as draft, gas pressure or flame signal.
- On a condensing unit, check the trap, drain and vent end for ice or blockage.
- Replace a part only if what it watches reads adequate and it still does not respond. Then run full cycles.
04
Keep on the record
5- Stored fault codes
- The step where the sequence stopped
- Readings taken at that step
- Nameplate photo
- Oil tank level, on oil systems
General guidance for a qualified person, not a finding about any home. The person on site decides.