Stop first if
- Ice or water is on outdoor wiring or controlsKeep clear of it. A qualified person kills power at the disconnect while standing somewhere dry. Otherwise call a licensed electrician.
- Panels must come off an inverter outdoor unitTreat it as live even when idle. A licensed tech locks out power, waits the label time, and measures the DC bus first.
01
Ask on the call
6Homeowner? These are the questions a good technician will ask you. Having the answers ready makes the first visit count.
- Was it in heat or cool mode at the time?
- What was the weather like: humid, foggy or icy?
- Does the ice ever clear on its own?
- Do you hear a whoosh when it switches?
- Does it show a code?
- Is there one indoor unit or several?
02
Bring
5- Remote probe thermometers
- Electrical meter
- Clamp-on current meter
- Clean filter
- Flashlight
03
Check on site
6- Record the mode and pull the wiring diagram.
- Judge any trip by the mode it happened in. Look at the coil that matters for that mode.
- On a multi-zone unit, compare what you see with the maker's documented routines first.
- A tech checks the valve coil and compares line temperatures across the reversing valve.
- A tech forces defrost by the maker's steps and watches the valve shift, outdoor fan stop and aux heat.
- If aux heat cycles, check airflow against the maker's minimum, then the limit. Remove every test jumper.
04
Keep on the record
5- Which mode it was in
- Photo of the ice pattern
- Line temperature readings at the valve
- Defrost test result
- Heater stage current
General guidance for a qualified person, not a finding about any home. The person on site decides.